Chinese
Position:home>Technology>
National remain consults manual of method of lab trace ultimate analysis
From;    Author:Stand originally
S. Caroli (European Union consults lab, italian Rome) summary: The management of guarantee system of instrument method, quality and chemical lab 3 person in should coordinate highly on the whole consistent. The country that the remain in animal of this live to must be opposite body and animal sex product implements quality guarantee system consults lab (NRLS) particularly important. And quality guarantee system is built just about the standard administers in the lab (GLP) and detect the lab operates criterion (EN45000 standard) over the foundation. According to the 23/96/EC guideline that the European Union issued on April 29, 1996, 4 European Unions consult lab (CRLS) be in charge of assisting an European Union each countries consult lab (the job that NRL) pursues rudimental respect. Rome consults lab (CRL) be in charge of consulting to each countries the lab is used at detecting of the arsenic in animal organization, cadmium, copper, mercuric, lead and other chemistry element detect the collection that the method has a system, form manual. The main purpose of this job depends on making all countries of the European Union consult the analytic method standard of the lab is uniform, make sure in same quality the condition falls, experimental result is had can compare a gender. Rome consults the lab undertakes every year twice editing to manual, this manual still can promote each countries to consult the information communication that the lab is improving aspect of existing analysis method. Keyword: Element of method of rudimental analysis, analysis, trace, quality assures, quality is controlled 1, 4 when the 86/469/EC guideline that the European Union issued brief introduction on April 29, 1986 set an European Union consult lab (CRLS) the principle of total division of labor that reachs side of job of remain of animal sex product in live body animal and particular job. The European Union issued 96/23/EC guideline again 1996, made clear a country to consult again lab and European Union consult the lab works in remain the grade system of the respect. 4 of the European Union consult the lab is respectively: The ISS of Rome of the AFSSA of the BGVV of Berlin of Dutch RIVM, Germany, France, Italy. These 4 consult although the lab assumes the job of different hangover, but its are basic duty and task are identical. As other as the European Union consult the working job of the lab is same, rome consults the lab is in charge of assisting each countries to consult the lab improves existing analytic method, make its more hasten is consistent. Develop even additionally establish new method. Consult to every country the lab, as far as possible complete and accurate executive lab administers a standard (GLP) with EN45000 series standard it is very important. Accordingly, each countries consult to the analysis that the lab uses to its masters actually of the method and use rate deserve attention very much. The valuable information of a few mature experiments and data were provided in this article, these information and data are Rome consults the lab passes an experiment to get confirming in a few years of in the past. 2, the analytic method that the content of manual consults to edit and improve them the lab is regularly to promote a state further, rome consults of a few groups of hangover with responsible to its lab detect the method undertook collection arranging. In " remain of European Union country consults manual of method of lab trace ultimate analysis " (the 96/23/EC guideline that issued on April 29, 1996) in the analytic method that accepts the trace class element that carried all current and wide application. The told about this manual content with detailed on certain level article. Included in manual each countries consult at that time of the arsenic that the lab uses, cadmium, copper, mercuric, lead detect method. The method that to make every country consults as far as possible the lab uses is stated hasten is standardized and have more can compare a gender, rome consults the lab offerred a pattern plate, each countries consult the lab provides relevant information according to this one pattern plate. This manual is divided in all for 6 parts, detailed sees a table 1. The main content of manual of element of watch 1 traceParagraphic part
Previous12 Next